PRTCG
PRTCG
Diagnostic Functions
Alarm when the followings occurred
• Ultra-high or ultra-low Temperature
• Thermocouple break, short or inverse
• Thermocouple is out of its position
• Heater break, short or overload
• Output device is damaged
• Fuse is broken
Protection Functions
• Wide power supply range, AC85~400V
• Thermocouple input protection,
prevent module damaged by mis-connection
• Thermocouple & heater inverse protection,
prevent thermocouple damaged by mis-connection
• Soft-start mode, avoid the moisture make the heater burn out
• High limit of load current
Power Supply | AC85~ 250V,50/60Hz | Consumed Power | < 2.5W |
Control Mode | Auto-PID / Manual | Output Type | Zero Cross / Phase Angle |
Sensor Type | Thermocouple J or K | Measurement Range | 0~500℃(32~932℉) |
Measurement Accuracy | ±0.25% FS | Setting Range | 0~450℃(32~842℉) |
Control Accuracy | ±0.25% FS | Display Resolution | 1 unit / 0.1unit |
Working Temperature | 0~55℃(32~131℉) | Load Capacity | 15A,3600W @ 240Vac |
Storage Temperature | -20~70℃(-4~158℉) | Switching Mode | Tact Switch |
Working Humidity | 10~80%RH(No condensing) |